A pinhole leak showed up in a vertical copper water line inside a first-floor wall. The wall was already opened, and our technician repaired the line with a new ProPress copper coupling.



The problem
A vertical copper water line inside a first-floor wall had a pinhole leak. The wall had already been opened before we arrived, so the pipe was exposed.
What our technician found
A pinhole leak is a tiny hole that wears through a copper pipe, often from corrosion working from the inside out. It can spray a fine mist or drip slowly inside the wall for a long time before anyone sees it. The usual fix is to remove the damaged piece and join the pipe again with a new fitting. A press fitting like ProPress seals the joint with a pressing tool, so no torch or open flame is needed inside the wall.
What we did
- Located the pinhole in the vertical copper water line through the opening in the wall.
- Repaired the pinhole with a new copper coupling, pressed on with a ProPress tool.
Parts used
- ProPress copper repair coupling
The result
The pinhole section of the copper line was repaired. The customer told us afterward that the technician was quick and fixed the issues they had.
Tips for Bethesda homeowners
- Water stains, bubbling paint, or a damp smell on a wall can mean a hidden pipe leak. Shut off the water and call a plumber before opening up more wall.
- One pinhole in copper pipe can be a sign of others. Keep an eye on nearby walls and ceilings after a repair.
- Leave the wall open until the repair has been checked for drips, then patch it.